Moreover, IntesisBox®includes all hardware required to manage/control Mitsubishi Heavy Industries indoor units without extra components needed. IntesisBox KNX - Modbus TCP master IntesisBox BACnet/. Therefore, the IntesisBox®Modbus Serveracts as a Modbus slave in the Modbus interface, allowing the Modbus master read and write in the Modbus registers. To do it so, IntesisBox performs as a Modbus Server, allowing poll and write requests from any Modbus master device. TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. devices or systems into other control systems (BACnet, KNX.) IntesisBox KNX - Modbus RTU master. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
#Intesisbox modbus server knx software
IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. Simple configuration, no point's configuration needs to be entered, just the communication parameters (IP address, baud rate…). Fixed Modbus address map, the register number identifies the element into the panel. Commands toward the panel are also supported (reset, silence, test elements…). The aim of this integration is to make accessible Modbus registers data and resources from a KNX system, as if it was a part of the own KNX system and vice-versa.


The value in the Modbus register indicating the state of the panel's element is fully configurable. Integrate any Modbus RTU or TCP server device, or both at the same time, with any KNX device or system. Monitoring of the panel elements (detectors, outputs…) through independent Modbus registers. IntesisBox connects to the RS232 port of the Honeywell panel, either through the RS232 port of the mother board, or through the isolated ISO-RS232 port (optional card). IntesisBox is a server device in case of Modbus TCP communication, or a slave device in case of Modbus RTU communication. IntesisBox allows Modbus TCP (Ethernet) or Modbus RTU (RS232 or RS485) communication, configurable by software.

Master Modbus RTU LinkBoxMB Configuration Software Monitor & Control your network of XLS 80 fire panels remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. Integrate your Honeywell fire panels into your Modbus master device or system (SCADA, BMS, PLC, HMI, TouchPanels…). The values received from Modbus become available to be read by the KNX system and vice-versa.IntesisBox ® Modbus Server - Honeywell XLS 80 datasheet v10 r13 eng Gateway for integration of Honeywell XLS 80 fire panels into Modbus (RTU and TCP) enabled control systems. Also, listen for any KNX telegram related to the internal points configured in it and acts accordingly to the configuration of the related point.įrom the Modbus system point of view, after the start-up process, the gateway listens for any read or write request, and serves any read request or performs any writing request of its internal points received from Modbus system. The aim of this integration is to make accessible KNX communication objects and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa. The IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of all parameters and functionalities of KNX installations from a Modbus BMS, SCADA, PLC or any other device working as a Modbus Master.įrom the KNX system point of view, in the start-up process of the gateway and also after a detection of a KNX bus reset, the gateway polls the KNX signals configured to be updated in this situation and maintain the received values in memory to be served to the Modbus system when requested. Integrate any KNX device or installation, with a Modbus BMS or any Modbus TCP or Modbus RTU controller.